Unagi

The only completely hands-free benchtop buffer exchange solution. Buffer exchange and concentration are two of the most annoying things you have to do before you can work with your sample. It takes forever, you physically have to be there and just when you think it’s done, you’re tweaking it again. Unagi is the first completely hands-free benchtop buffer exchange solution that’s made to take this not-so-fun task off your plate — so you can be anywhere else instead of tied to your bench.
 Protein
 mRNA & DNA
 AAV

  • Yêu Cầu Báo Giá        Xem Thêm  
  • Giới Thiệu

    Served up a’ la carte

    Drop 1 to 8 of your samples into some Unas, twist them into the holder and boom, they’re ready to go. Each Una can handle from 0.5 to 8 mL of sample. They have a regenerated cellulose membrane with a 10 kDa molecular weight cutoff to make sure your samples stay put, don’t get absorbed, and the liquid passes right through — with ≥96% recovery.

    The secret sauce

    Unagi has the recipe for UF/DF buffer exchange dialed in. It checks the initial sample volumes with an ultrasonic sensor so it knows what it’s working with. Next, it pressurizes each Una while gently mixing your samples to get things flowing. It checks the volume again and refills each Una with your new buffer. This process repeats until Unagi hits your target exchange percentage and volume.

    Put in your order

    Unagi is super easy to use — so everyone can get a taste. First choose the type of experiment you want to run. Then tell it what kind of molecule you’re exchanging, how much you have, and what buffer to exchange into. Last step is to input percent exchange and final volume if you want to concentrate your sample.

    Get your fill

    Now you just follow Unagi’s step-by-step instructions. Load up the tray of Unas filled with your samples in the front. Fill Falcon tubes with your buffers and plop them in on the left. Throw some tip racks in on the right and Unagi is ready to go. No joke, it’s that easy.

    Let it roll

    Hit start and let Unagi do its thing. Now you can walk away, but feel free to check on Unagi whenever you want. It’s tracking the number of exchange cycles completed, provides info on the current filtration cycle, and displays the percent exchanged for each sample. If you’re in a pinch, you can pause the run to take out samples that are done before the rest or keep it rolling. Either way, Unagi will tell you when it’s a wrap.

    Take it down

    Some samples are too dilute and need a little TLC. Unagi can concentrate these samples to a usable range. Choose the Reduce Sample Volume application and Unagi will concentrate up to eight dilute samples from 48 mL down to 8 mL in a single run. From there, you can follow up with a buffer exchange run or concentrate them further.

    Get the check

    Unagi tracks every single move it made and documents everything that happened during the run. It kicks out a detailed report of final volumes and concentrations, flow rates for every cycle, and the final percent exchanged for each sample. These reports can easily be placed in a lab notebook, uploaded to a LIMs, or hung on your refrigerator.

    Mô Tả

    Application :

    Buffer exchange volume range
    0.5-8 mL

    Formulations
    Up to 8 formulations in parallel

    Sample types
    Antibodies and other proteins, nucleic acids, and AAVs

    Exchange time at full volume (96%, at 10 mg/mL IgG)
    4.5 hours*

    Protein concentration (range)
    Up to 200 mg/mL*

    Target concentration accuracy
    ±10%*

    Sample recovery
    ≥96%*

    System :

    Volume measurement: Ultrasonic sensor

    Exchange pressures
    15, 30 or 60 psi

    Operating temperature
    Room temperature

    Buffer exchange orbital mixing
    Optimized at 700 rpm Duty cycle programmable

    Physical
    63 cm W x 57 cm D x 66 cm H; 65 kg

    Electrical
    Voltage 100-260 VAC, 50-60 Hz

    Nitrogen or CDA requirement
    Pressure 0.55–0.9 MPa (80–130 psi) Flow rate 40 L/s (85 cfm) minimum

    Consumables :

    Una
    10 kDa, regenerated cellulose

    Disposable tips
    1000 μL non- ltered, automatic re-use up to 12 times per exchange

    Dispense precision
    0.3-8 mL: ≤1%

    *Sample and formulation dependent.